约60kg
白蜡机最低限度的使用、维护和散热空间:
打印机后方至少35厘米(13.78英寸)
打印机左右两侧至少60厘米(23.62英寸)
摆放设备台面上方至少120厘米(47.24英寸)
氧气机工作空间要求:
可以放置在白蜡机附近的地面上,通过气管连接到白蜡机。
氧气机前后左右至少有20厘米进出气以及散热空间确保稳定供氧。
白蜡机电气要求
在供电不稳定的情况下,推荐配置UPS(不间断电源)来保护白蜡机。
确保白蜡机稳定运行,必须满足以下所有电气要求:
1. 正常市电标准供电
2. 不要将任何额外的设备接入电源电路
3. 白蜡机需要220V电压,电流不少于8A
4. 氧气机需要220V电压,电流不少于5A
5.将白蜡机和氧气机分别接入单独的浪涌防雷保护器或UPS
English is HERE!
General Environment Requirements
System Isolation: It is recommended to maintain a certain distance between the White Wax machine and other temperature control systems.
Airflow Management: Do not direct airflow from air conditioners (wall-mounted, floor-standing, or central), fans, or heaters toward the machine or its installation site.
Light Exposure: Do not expose the machine to direct sunlight or ultraviolet (UV) radiation.
Placement Safety: * Avoid placing the machine near doorways.
Keep the printer and oxygen generator away from water sources, such as sinks, bathtubs, and ultrasonic cleaners.
Do not place the machine next to other operating equipment, such as polishing machines, wax injectors, or purple wax machines.
Stability: Avoid environments with drastic temperature fluctuations.
Temperature and Humidity Specifications
Ensure the room temperature remains within the following range:
Minimum Temperature: 22°C (72°F).
Maximum Temperature: 28°C (82°F).
Humidity (Important): Maintain humidity levels below 45%.
Air Quality and Ventilation Recommendations
The White Wax machine must be operated in a clean-air environment. High concentrations of impurities in the air can contaminate the materials and printed parts, and may also reduce the lifespan of the oxygen generator.
Ventilation: The room must have adequate airflow (minimum 0.03 square meters per minute) to ensure the heat generated by the machine is sufficiently dissipated.
AC Distance: Air conditioning vents should be at least 3 meters away from the printer, and the airflow direction must not point directly at the machine.
Environmental Hazards: Ensure the workspace is free from the following:
Dust
Smoke
Steam/Vapor
Operational Space and Placement Specifications
Notice: Incorrect placement of the White Wax machine and oxygen generator may lead to damage or negatively affect print quality. Please strictly follow these installation space specifications.
Platform Requirements
The machine must be placed on a platform that is stable, firm, and level.
Minimum Clearance for Maintenance and Heat Dissipation
Rear: At least 35 cm (13.78 in).
Sides (Left/Right): At least 60 cm (23.62 in).
Above: At least 120 cm (47.24 in) from the tabletop.
Oxygen Generator Space Requirements
The generator can be placed on the floor near the White Wax machine and connected via an air tube.
Ensure at least 20 cm of clearance on all sides (front, back, left, and right) for air intake and heat dissipation to ensure a stable oxygen supply.
Electrical Requirements
In areas with unstable power supply, it is recommended to use a UPS (Uninterruptible Power Supply) to protect the machine.
To ensure stable operation, all the following electrical requirements must be met:
Standard municipal power supply.
Do not connect any additional equipment to the same power circuit as the machine.
White Wax Machine: Requires 220V voltage and a current of no less than 8A.
Oxygen Generator: Requires 220V voltage and a current of no less than 5A.
Connect the White Wax machine and the oxygen generator to separate surge protectors or individual UPS units.